name, description, version, author, license, platforms, metadata
| name | description | version | author | license | platforms | metadata | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ipmi-bmc-management | Use when working with IPMI/BMC out-of-band server mgmt. | 1.0.0 | Hermes Agent | MIT |
|
|
IPMI / BMC Out-of-Band Management
Manage servers out-of-band via their BMC (Baseboard Management Controller). Covers read-only inventory, sensor/thermal readout, firmware version checks, and the modern Redfish REST API. Credentials live in fact_store, never in this skill.
Install
sudo apt-get install -y ipmitool # CLI (also: freeipmi-tools)
ipmitool — read-only inventory
ipmitool -I lanplus -H <bmc-ip> -U <user> -P <pass> -C 3 <cmd>
Useful read-only commands:
mc info— BMC identity (manufacturer, product ID, firmware rev, IPMI version)fru print— board serial, mfg date, product infosensor list/sdr list— thermals, voltages, fans, GPU tempschassis status— power state, fault flags, power-restore policypower status— on/offlan print— BMC network config (IP, MAC, gateway, cipher suites)user list— configured BMC accountssel info/sel list— system event log (check for full/overflow)
CRITICAL: Supermicro cipher-suite quirk
Supermicro BMCs (H12SSL-i and similar) FAIL the default RMCP+ cipher suite (17 / SHA256) with:
Error in open session response message : invalid role
Error: Unable to establish IPMI v2 / RMCP+ session
Fix: force cipher suite 3 with -C 3. This is the single most common
failure when scripting Supermicro IPMI. -C 17 and -L ADMINISTRATOR do NOT
help — only -C 3 works. IPMI 1.5 (-I lan) also works but is insecure.
Redfish — the modern API (preferred for firmware inventory)
Supermicro BMCs expose a full Redfish REST API. Use it for firmware version checks — it's cleaner than raw OEM IPMI commands (which often return "Request data length invalid").
# Root (confirms Redfish + vendor)
curl -sk -u 'USER:PASS' https://<bmc-ip>/redfish/v1/
# Firmware inventory — BMC, BIOS, CPLD versions in one shot
curl -sk -u 'USER:PASS' https://<bmc-ip>/redfish/v1/UpdateService/FirmwareInventory
# Per-component version
curl -sk -u 'USER:PASS' https://<bmc-ip>/redfish/v1/UpdateService/FirmwareInventory/BMC
curl -sk -u 'USER:PASS' https://<bmc-ip>/redfish/v1/UpdateService/FirmwareInventory/BIOS
# System info (BiosVersion, Model, ProcessorSummary)
curl -sk -u 'USER:PASS' https://<bmc-ip>/redfish/v1/Systems/1
FirmwareInventory members are named BMC, BIOS, Motherboard_CPLD_1,
GPU<n> etc. Each returns Version, Updateable, ReleaseDate. GPUs show
Version: None (not firmware-managed via BMC).
Firmware currency check
- Read current versions via Redfish FirmwareInventory (BMC + BIOS + CPLD).
- Cross-check against Supermicro download center:
https://www.supermicro.com/en/support/resources/downloadcenter/firmware/MBD-<board>/BIOS(search result snippets list "BIOS Revision: X.Y" and "BMC Firmware Revision: X.Y.Z"). - Report the gap. Note: Supermicro BMC downgrades are NOT supported after security updates — upgrades are one-way.
Firmware UPDATE (flash) — method decision
The H12/H12SS bundle ships SAA (SuperServer Automation Assistant) UEFI, NOT
SUM. SUM is the older in-band updater; the H12 firmware zip contains
SAA.efi + flash.nsh. Two hard rules from Supermicro's own package readme:
- "Using AFU tool will end up with the BIOS corruption. It should never be used!" — the AMI AFU flasher is forbidden on H12.
- BIOS flash on H12SS-and-newer MUST go through the BMC — DOS/EFI standalone BIOS flashing is no longer supported. The BMC web UI uploads the .bin to the BMC flashdisk and the BMC does the flash.
| Method | License? | Notes |
|---|---|---|
| BMC web UI → Maintenance → Firmware Management | No | The supported path for BOTH BMC and BIOS on H12. Upload the .bin; BMC does the flash. ~2.5 min BMC, a few min BIOS. |
SAA UEFI shell (flash.nsh <rom> <user> <pw>) |
No | In-band alternative; requires booting host into EFI shell. |
| Redfish SimpleUpdate | YES (DCMS) | Returns SMC.1.0.OemLicenseNotPassed — "Not licensed... DCMS needed" |
| Redfish OEM SmcUpdateService.Install | No | Available (Targets + InstallOptions) but web UI is the documented path |
| ipmitool hpm upgrade | No | Only for .hpm images; Supermicro ships .bin |
Probe the license block before assuming Redfish works:
curl -sk -u 'U:P' https://<bmc>/redfish/v1/UpdateService/SimpleUpdateActionInfo
— if it returns OemLicenseNotPassed, SimpleUpdate is out.
Upgrade order: BMC first (closes BMC CVEs, one-way), then BIOS (closes CPU microcode/AGESA CVEs). BIOS flash requires host OFF. Apply BMC and BIOS in one session — mismatched BIOS/BMC version pairs can hang at POST code FF.
Recovery safety net: Supermicro BMCs keep quad-image redundancy —
FirmwareInventory lists BMC/Backup_BMC/Golden_BMC/Staging_BMC (same for
BIOS). A failed flash can boot from Backup/Golden via the web UI "Recover"
option or Redfish OEM Install with InstallOptions=["Recover"].
Post-flash checks: re-test the cipher suite (newer BMC firmware may switch from cipher 3 to 17/SHA256), re-verify login, and re-read FirmwareInventory to confirm the new version. A DHCP BMC may also change IP after reset — re-find by MAC (fixed) via ARP scan if the IP moves.
Security advisories to check
- Supermicro Security Center: https://www.supermicro.com/en/support/security_center
- Supermicro BMC advisories (e.g. July 2026 CVE-2026-3821, CVSS 8.8, SMASH arbitrary code execution — fix is a BMC firmware update).
- AMD bulletins (e.g. AMD-SB-7054 / CVE-2025-54502, CVSS 7.1, affects EPYC 7002 "Rome" — fix is RomePI 1.0.0.P AGESA via BIOS update). Cross-check the board's CPU generation against the bulletin's affected list.
SEL (system event log) health
sel info shows Percent Used and Overflow. If 100% full with
Overflow: true, new events are being DROPPED. Clearing is a WRITE op —
confirm with the operator before sel clear. Supermicro OEM events often
decode as Unknown #0xff (raw vendor events, not standard IPMI).
Security notes
- Legacy IPMI (RMCP+ cipher 3) is weak; prefer Redfish over HTTPS where possible.
- Supermicro publishes BMC security advisories (e.g. July 2026, CVE-2026-3821, up to 8.8 CVSS). Old BMC firmware predates these — flag for update.
lan printshowsBad Password Threshold(default 3) and lockout interval — repeated bad attempts lock the account. Don't brute-force.
Pitfalls
- Cipher 17 fails on Supermicro — always
-C 3(see above). - Raw OEM commands (
raw 0x30 0x90 ...) for BIOS version return "Request data length invalid" on many Supermicro boards — use Redfish instead. - BMC up ≠ host up. The BMC can report "System Power: on" while the host OS is unreachable (no route to host / ARP INCOMPLETE). Verify host reachability separately (SSH port probe) before assuming the box is down.
- Credentials in fact_store, not here. Look up the BMC IP/user/pass in fact_store before connecting; never hardcode passwords in a skill.
- Supermicro download-center PDFs are bot-blocked (403). Release-notes PDFs
and the firmware download page return 403 to curl/SearXNG/browser. BUT the
firmware itself is freely mirrored and NOT blocked — download the actual
.bin files from
https://ftp.abacus.cz/support/FW/MB/SUPERMICRO/BIOS/<board>/(orhttps://sm.t3x.net/), then verify SHA256. Thomas-Krenn also mirrors tested-stable bundles athttps://www.thomas-krenn.com/en/download?product=<id>(their/redx/tools/mb_download.php/...links are curl-able). Only the Supermicro.com release-notes PDFs stay behind the wall — use Thomas-Krenn wiki changelogs or search-result snippets for those.
References